{"id":284983,"date":"2026-08-16T17:54:27","date_gmt":"2026-08-16T15:54:27","guid":{"rendered":"https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/"},"modified":"2026-08-16T17:54:27","modified_gmt":"2026-08-16T15:54:27","slug":"energy-density-duration-stationary-storage","status":"publish","type":"post","link":"https:\/\/www.heiwit.com\/en\/densita-energetica-durata-storage-stazionario\/","title":{"rendered":"Energy density versus lifespan: which really matters in stationary storage"},"content":{"rendered":"<p>In the comparison between storage technologies, there is one figure that is cited more than any other: energy density, watt-hours per kilogram. It is the parameter that has driven twenty years of battery development, for a simple reason: batteries have mainly been developed for things that move. A phone, a tool, a car.<\/p>\n<p>For stationary storage, that number matters much less than people think, and this article explains why\u2014and which parameter to look at instead.<\/p>\n<h2>The compromise, put plainly<\/h2>\n<p>Le <a href=\"https:\/\/www.heiwit.com\/en\/polyanionic-nfpp-cells\/\">polyanionic NFPP cells<\/a> they have an energy density of <strong>100\u2013120 Wh\/kg<\/strong>. Lithium iron phosphate is between 120 and 180, and nickel-manganese-cobalt is between 220 and 280.<\/p>\n<div class=\"hw-table-wrap\">\n<table>\n<thead>\n<tr>\n<th>Chemistry<\/th>\n<th>Energy density (Wh\/kg)<\/th>\n<th>Life cycles<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Lead-acid<\/td>\n<td>30\u201350<\/td>\n<td>300\u2013500<\/td>\n<\/tr>\n<tr>\n<td>NMC \/ NCA<\/td>\n<td>220\u2013280<\/td>\n<td>800<\/td>\n<\/tr>\n<tr>\n<td>LFP<\/td>\n<td>120\u2013180<\/td>\n<td>&gt; 6,000<\/td>\n<\/tr>\n<tr>\n<td>Polyanionic cellulose (PAC)<\/td>\n<td><strong>100\u2013120<\/strong><\/td>\n<td><strong>9.000<\/strong> (DoD 95%)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<p>Read from left to right, the table looks like a league table in which sodium comes last. Read across the two columns together, it tells another story: <strong>the two quantities move in opposite directions<\/strong>. Nickel-manganese-cobalt has the highest density and the lowest number of cycles. Polyanionic sodium has the lowest density and the highest number of cycles. It is not a coincidence, it is physics.<\/p>\n<h2>Why can\u2019t you have both?<\/h2>\n<p>A cathode stores energy by trapping ions within a crystalline structure. There are two ways of designing that structure, and they are at odds with one another.<\/p>\n<p>You can return it <strong>rich yet light<\/strong>: a few atoms that do not take part in the reaction, plenty of sites available for ions, mass concentrated where it is needed. This is the approach taken by layered oxides, and it produces the highest specific energy. The downside is that the structure expands and contracts with every cycle, and, as a result of this \u2018breathing\u2019, it loses its order.<\/p>\n<p>Or you can make it <strong>rigid<\/strong>: A three-dimensional framework is formed from phosphate and pyrophosphate groups that hold the lattice in place. Ions move in and out without the structure becoming distorted. The trade-off is that these groups have mass, and that mass does not store energy \u2014 it is merely a supporting structure.<\/p>\n<blockquote>\n<p>The energy density that the polyanionic cathode lacks is precisely the weight of the framework that gives it its longevity.<\/p>\n<\/blockquote>\n<p>Asking a chemist to do both is like asking a building to have thin walls and withstand an earthquake.<\/p>\n<h2>How much does it really weigh, practically speaking<\/h2>\n<p>Translated to a home system: for the same installed capacity, a polyanionic sodium battery is bulkier and heavier than a lithium iron phosphate one. On a cabinet that stands against a wall, in a garage or in a plant room, this translates into a few centimetres of depth and a few tens of kilos more.<\/p>\n<p>It is worth asking when this constitutes a real problem. If the battery has to go up onto a roof, fit into a narrow pre-existing compartment, or be wall-mounted on a lightweight structure, volume and weight must be checked during the site survey \u2014 just like any other installation constraint. In a floor-mounted technical room, which is by far the most frequent situation, the difference has no practical consequences.<\/p>\n<p>What never changes is this: <strong>a stationary battery is lifted only once, on the day of installation<\/strong>. From that point on, watt-hours per kilogram no longer have any bearing on anything. Not on performance, not on the electricity bill, not on lifespan.<\/p>\n<h2>The key figure to look at<\/h2>\n<p>If energy density is not the right criterion for a steady state, what is?<\/p>\n<p>It is the <strong>cost of energy actually cycled<\/strong> over the system\u2019s lifetime \u2014 in the literature <em>LCOS<\/em>, <em>Levelised Cost of Storage<\/em>. As a rough estimate, this is calculated by dividing the total cost of the system by the amount of energy that the system will be able to transmit before reaching the end of its service life.<\/p>\n<p>The point is that <strong>the denominator consists of cycles<\/strong>. Two batteries with the same list price and the same capacity, but with a different number of cycles, have profoundly different costs per accumulated kWh \u2014 and this difference is not visible in any comparison made on purchase price.<\/p>\n<p>There are also three factors that the list price does not reflect:<\/p>\n<ul>\n<li>the\u2019<strong>round-trip efficiency<\/strong>, because every point lost represents energy that is dissipated as heat during every single cycle, throughout the system\u2019s lifetime. The NFPP cells measure 97%;<\/li>\n<li>the <strong>usable discharge depth<\/strong>, because a rated capacity of which only a portion can be utilised is an inflated rated capacity. The 9,000 cycles of the NFPP cells are specified at 95% DoD, i.e. by discharging the battery almost completely in each cycle;<\/li>\n<li>the <strong>converted to actual temperatures<\/strong> at the installation site, not at 25 \u00b0C in a laboratory \u2014 the subject of <a href=\"https:\/\/www.heiwit.com\/en\/sodium-batteries-low-temperature\/\">a separate in-depth analysis<\/a>.<\/li>\n<\/ul>\n<p>We have applied this method to the current generation of Heiwit systems in <a href=\"https:\/\/www.heiwit.com\/en\/accumulated-energy-cost-lcos\/\">an article dedicated to LCOS calculation<\/a>. The updated figures for the polyanionic cell generation will be published upon launch, once the system specifications have been finalised.<\/p>\n<h2>When the choice would be the opposite<\/h2>\n<p>For the sake of intellectual honesty, it must be pointed out where this compromise falls short.<\/p>\n<p>In an electric vehicle every kilogram of battery is mass to accelerate, brake and carry for the entire life of the vehicle: there energy density is not just one parameter among others, it is <em>the<\/em> parameter. The same goes for portable electronics, cordless tools and any application where weight costs you with every use.<\/p>\n<p>This is why sodium will not replace lithium everywhere, and anyone presenting it as a technology that \u201cbeats lithium\u201d is oversimplifying to the point of being wrong. They are chemistries with different vocations. Stationary storage paired with photovoltaics is the application where the properties of polyanionic sodium \u2014 lifespan, thermal stability, cold tolerance, independence from lithium and cobalt \u2014 are worth more than what it gives up.<\/p>\n<h2>Frequently asked questions<\/h2>\n<h3>Is a sodium battery larger than a lithium one?<\/h3>\n<p>Yes, for the same capacity in kWh. The difference is a few centimetres and a few tens of kilograms on a home system, and only needs to be checked during a site inspection if the available space is restricted.<\/p>\n<h3>Does lower Wh\/kg mean it performs worse?<\/h3>\n<p>No. Energy density describes how much energy is contained in one kilogram, not how much is returned. The energy returned per cycle depends on efficiency \u2014 97% for NFPP cells \u2014 and the usable depth of discharge.<\/p>\n<h3>What is LCOS?<\/h3>\n<p><em>Levelised Cost of Storage<\/em>the cost of each kWh passing through the battery over its entire lifetime, obtained by dividing the total system cost by the total energy cycled. It is the parameter that makes batteries with different prices, capacities and lifespans comparable.<\/p>\n<h3>Why don't we design a dense and rigid cathode together?<\/h3>\n<p>Because stiffness is achieved by adding groups to the lattice that hold it in position, and those groups have a mass that does not participate in energy storage. Density and structural stability compete for the same space and the same mass.<\/p>","protected":false},"excerpt":{"rendered":"<p>Nel confronto fra tecnologie di accumulo c&#8217;\u00e8 un numero che viene citato pi\u00f9 di ogni altro: la densit\u00e0 energetica, i watt-ora per chilogrammo. \u00c8 il parametro che ha guidato vent&#8217;anni di sviluppo delle batterie, per una ragione semplice: le batterie si sono sviluppate soprattutto per cose che si muovono. Un telefono, un attrezzo, un&#8217;auto. Per [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"categories":[42,122],"tags":[],"class_list":["post-284983","post","type-post","status-publish","format-standard","hentry","category-batterie-agli-ioni-di-sodio","category-studi-e-ricerche"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Densit\u00e0 energetica o durata? Il criterio per lo storage | Heiwit<\/title>\n<meta name=\"description\" content=\"Perch\u00e9 i Wh\/kg contano poco in un accumulo stazionario e quale parametro guardare al loro posto: cicli, efficienza, profondit\u00e0 di scarica e LCOS.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.heiwit.com\/en\/energy-density-duration-stationary-storage\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Densit\u00e0 energetica o durata? Il criterio per lo storage | Heiwit\" \/>\n<meta property=\"og:description\" content=\"Perch\u00e9 i Wh\/kg contano poco in un accumulo stazionario e quale parametro guardare al loro posto: cicli, efficienza, profondit\u00e0 di scarica e LCOS.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.heiwit.com\/en\/energy-density-duration-stationary-storage\/\" \/>\n<meta property=\"og:site_name\" content=\"Heiwit - Batterie agli ioni di Sodio\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/heiwit.italia\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-16T15:54:27+00:00\" \/>\n<meta name=\"author\" content=\"Ufficio Tecnico Heiwit\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Ufficio Tecnico Heiwit\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/densita-energetica-durata-storage-stazionario\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/densita-energetica-durata-storage-stazionario\\\/\"},\"author\":{\"name\":\"Ufficio Tecnico Heiwit\",\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#\\\/schema\\\/person\\\/ae9ed97deab943ecf7ae6cd0b69c0701\"},\"headline\":\"Densit\u00e0 energetica contro durata: quale conta davvero nello storage stazionario\",\"datePublished\":\"2026-08-16T15:54:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/densita-energetica-durata-storage-stazionario\\\/\"},\"wordCount\":1113,\"publisher\":{\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#organization\"},\"articleSection\":[\"Batterie agli ioni di sodio\",\"Studi e ricerche\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/densita-energetica-durata-storage-stazionario\\\/\",\"url\":\"https:\\\/\\\/www.heiwit.com\\\/densita-energetica-durata-storage-stazionario\\\/\",\"name\":\"Densit\u00e0 energetica o durata? Il criterio per lo storage | Heiwit\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#website\"},\"datePublished\":\"2026-08-16T15:54:27+00:00\",\"description\":\"Perch\u00e9 i Wh\\\/kg contano poco in un accumulo stazionario e quale parametro guardare al loro posto: cicli, efficienza, profondit\u00e0 di scarica e LCOS.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/densita-energetica-durata-storage-stazionario\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.heiwit.com\\\/densita-energetica-durata-storage-stazionario\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/densita-energetica-durata-storage-stazionario\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.heiwit.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Densit\u00e0 energetica contro durata: quale conta davvero nello storage stazionario\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#website\",\"url\":\"https:\\\/\\\/www.heiwit.com\\\/\",\"name\":\"Heiwit\",\"description\":\"Transizione energetica sostenibile\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.heiwit.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#organization\",\"name\":\"Heiwit S.p.A.\",\"url\":\"https:\\\/\\\/www.heiwit.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.heiwit.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/www.heiwit.com\\\/wp-content\\\/uploads\\\/2025\\\/09\\\/logo.png\",\"width\":834,\"height\":239,\"caption\":\"Heiwit S.p.A.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/heiwit.italia\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/heiwit\\\/\",\"https:\\\/\\\/www.youtube.com\\\/@Heiwit.italia\",\"https:\\\/\\\/www.instagram.com\\\/heiwit.spa\\\/\"],\"legalName\":\"Heiwit S.p.A.\",\"telephone\":\"+3903321730555\",\"vatID\":\"IT03980400125\",\"taxID\":\"03980400125\",\"description\":\"Produzione e installazione di sistemi di accumulo agli ioni di sodio per impianti fotovoltaici residenziali, commerciali e industriali.\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Via Carlo Robbioni, 2\",\"postalCode\":\"21100\",\"addressLocality\":\"Varese\",\"addressRegion\":\"VA\",\"addressCountry\":\"IT\"},\"location\":{\"@type\":\"Place\",\"name\":\"Sede operativa Heiwit\",\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Via Papa Giovanni XXIII, 126\",\"postalCode\":\"21042\",\"addressLocality\":\"Caronno Pertusella\",\"addressRegion\":\"VA\",\"addressCountry\":\"IT\"}},\"contactPoint\":{\"@type\":\"ContactPoint\",\"contactType\":\"sales\",\"telephone\":\"+3903321730555\",\"availableLanguage\":[\"Italian\",\"English\",\"German\"]},\"areaServed\":[\"IT\",\"DE\",\"CH\",\"AT\",\"FR\",\"ES\",\"PL\",\"RO\",\"CZ\",\"SE\",\"GR\",\"NL\",\"HU\",\"PT\",\"GB\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.heiwit.com\\\/#\\\/schema\\\/person\\\/ae9ed97deab943ecf7ae6cd0b69c0701\",\"name\":\"Ufficio Tecnico Heiwit\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e4d7c19d681897eef8bc3be5094ea6f903e14247c031c8eb3ccee6380f3bf1a1?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e4d7c19d681897eef8bc3be5094ea6f903e14247c031c8eb3ccee6380f3bf1a1?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e4d7c19d681897eef8bc3be5094ea6f903e14247c031c8eb3ccee6380f3bf1a1?s=96&d=mm&r=g\",\"caption\":\"Ufficio Tecnico Heiwit\"},\"description\":\"Contenuti a cura dell'Ufficio Tecnico di Heiwit S.p.A., produttore italiano di sistemi di accumulo agli ioni di sodio. Il team segue progettazione, dimensionamento e messa in servizio degli impianti, la qualifica dei fornitori di celle e il monitoraggio del parco installato.\",\"sameAs\":[\"https:\\\/\\\/www.heiwit.com\"],\"url\":\"https:\\\/\\\/www.heiwit.com\\\/en\\\/author\\\/master_heiwit\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Energy density or runtime? The key factor for storage | Heiwit","description":"Why Wh\/kg matter little in a stationary storage system and which parameter to look at instead: cycles, efficiency, depth of discharge, and LCOS.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.heiwit.com\/en\/energy-density-duration-stationary-storage\/","og_locale":"en_GB","og_type":"article","og_title":"Densit\u00e0 energetica o durata? Il criterio per lo storage | Heiwit","og_description":"Perch\u00e9 i Wh\/kg contano poco in un accumulo stazionario e quale parametro guardare al loro posto: cicli, efficienza, profondit\u00e0 di scarica e LCOS.","og_url":"https:\/\/www.heiwit.com\/en\/energy-density-duration-stationary-storage\/","og_site_name":"Heiwit - Batterie agli ioni di Sodio","article_publisher":"https:\/\/www.facebook.com\/heiwit.italia","article_published_time":"2026-08-16T15:54:27+00:00","author":"Ufficio Tecnico Heiwit","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Ufficio Tecnico Heiwit","Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/#article","isPartOf":{"@id":"https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/"},"author":{"name":"Ufficio Tecnico Heiwit","@id":"https:\/\/www.heiwit.com\/#\/schema\/person\/ae9ed97deab943ecf7ae6cd0b69c0701"},"headline":"Densit\u00e0 energetica contro durata: quale conta davvero nello storage stazionario","datePublished":"2026-08-16T15:54:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/"},"wordCount":1113,"publisher":{"@id":"https:\/\/www.heiwit.com\/#organization"},"articleSection":["Batterie agli ioni di sodio","Studi e ricerche"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/","url":"https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/","name":"Energy density or runtime? The key factor for storage | Heiwit","isPartOf":{"@id":"https:\/\/www.heiwit.com\/#website"},"datePublished":"2026-08-16T15:54:27+00:00","description":"Why Wh\/kg matter little in a stationary storage system and which parameter to look at instead: cycles, efficiency, depth of discharge, and LCOS.","breadcrumb":{"@id":"https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.heiwit.com\/densita-energetica-durata-storage-stazionario\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.heiwit.com\/"},{"@type":"ListItem","position":2,"name":"Densit\u00e0 energetica contro durata: quale conta davvero nello storage stazionario"}]},{"@type":"WebSite","@id":"https:\/\/www.heiwit.com\/#website","url":"https:\/\/www.heiwit.com\/","name":"Heiwit","description":"Sustainable energy transition","publisher":{"@id":"https:\/\/www.heiwit.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.heiwit.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/www.heiwit.com\/#organization","name":"Heiwit S.p.A.","url":"https:\/\/www.heiwit.com\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.heiwit.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.heiwit.com\/wp-content\/uploads\/2025\/09\/logo.png","contentUrl":"https:\/\/www.heiwit.com\/wp-content\/uploads\/2025\/09\/logo.png","width":834,"height":239,"caption":"Heiwit S.p.A."},"image":{"@id":"https:\/\/www.heiwit.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/heiwit.italia","https:\/\/www.linkedin.com\/company\/heiwit\/","https:\/\/www.youtube.com\/@Heiwit.italia","https:\/\/www.instagram.com\/heiwit.spa\/"],"legalName":"Heiwit S.p.A.","telephone":"+3903321730555","vatID":"IT03980400125","taxID":"03980400125","description":"Production and installation of sodium-ion battery storage systems for residential, commercial, and industrial photovoltaic plants.","address":{"@type":"PostalAddress","streetAddress":"Via Carlo Robbioni, 2","postalCode":"21100","addressLocality":"Varese","addressRegion":"VA","addressCountry":"IT"},"location":{"@type":"Place","name":"Sede operativa Heiwit","address":{"@type":"PostalAddress","streetAddress":"Via Papa Giovanni XXIII, 126","postalCode":"21042","addressLocality":"Caronno Pertusella","addressRegion":"VA","addressCountry":"IT"}},"contactPoint":{"@type":"ContactPoint","contactType":"sales","telephone":"+3903321730555","availableLanguage":["Italian","English","German"]},"areaServed":["IT","DE","CH","AT","FR","ES","PL","RO","CZ","SE","GR","NL","HU","PT","GB"]},{"@type":"Person","@id":"https:\/\/www.heiwit.com\/#\/schema\/person\/ae9ed97deab943ecf7ae6cd0b69c0701","name":"Technical Department Heiwit","image":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/secure.gravatar.com\/avatar\/e4d7c19d681897eef8bc3be5094ea6f903e14247c031c8eb3ccee6380f3bf1a1?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e4d7c19d681897eef8bc3be5094ea6f903e14247c031c8eb3ccee6380f3bf1a1?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e4d7c19d681897eef8bc3be5094ea6f903e14247c031c8eb3ccee6380f3bf1a1?s=96&d=mm&r=g","caption":"Ufficio Tecnico Heiwit"},"description":"Content provided by the Technical Department of Heiwit S.p.A., an Italian manufacturer of sodium-ion storage systems. The team is responsible for the design, sizing and commissioning of the systems, the qualification of cell suppliers and the monitoring of the installed base.","sameAs":["https:\/\/www.heiwit.com"],"url":"https:\/\/www.heiwit.com\/en\/author\/master_heiwit\/"}]}},"_links":{"self":[{"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/posts\/284983","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/comments?post=284983"}],"version-history":[{"count":0,"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/posts\/284983\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/media?parent=284983"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/categories?post=284983"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.heiwit.com\/en\/wp-json\/wp\/v2\/tags?post=284983"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}